12 

1-800-735-6200

VI-J00

MiniMod

DC-DC Converters

25 to 100 Watts

Product Highlights

The VI-J00 MiniMod family establishes

a new standard in component-level 

DC-DC converters. This “junior” size

complement to the higher power VI-200

family offers up to 100W of isolated and

regulated power in a board mounted

package. At one-half the size and twice

the power density of previous 100W

modules, and with a maximum operating

temperature rating of 100˚C, the MiniMod

opens new horizons for board-mounted

(distributed) power architectures. 

Utilizing Vicor’s “zero-current-

switching” forward converter technology,

proven by an installed base of over 

8 million units, the MiniMod family

combines state of the art power density

with the efficiency, low noise and

reliability required by next generation

power systems.

Packaging Options

SlimMods™, high power density,

flangeless packages and FinMods™,

featuring integral finned heatsinks.

SlimMod: Option suffix: - S

Example: VI - JXX - XX

- S

FinMod: Option suffix: - F1 and - F2

Examples:

VI - JXX - XX -

F1, 0.75" height

VI - JXX - XX -

F2, 1.00" height

Converter Selection Chart

VI-J

Input Voltage

Brownout

/

Nominal

Range

Transient

*

0 = 12V

10 - 20V(5)

n/a

22V

1 = 24V

21 - 32V(2)

18V

36V

W = 24V

18 - 36V(2)

n/a

n/a

2 = 36V

21 - 56V(6)

18V

60V

3 = 48V

42 - 60V(3)

36V

72V

N = 48V

36 - 76V(2)

n/a

n/a

4 = 72V

55 - 100V(2)

45V

110V

T = 110V

66 - 160V(2)

n/a

n/a

5 = 150V

100 - 200V(2)

85V

215V

6 = 300V

200 - 400V(3)

170V

425V

7 = 150/300V 100 - 375V(6)

90V

n/a

Max. Output For 5V Outputs > 5V Outputs < 5V Outputs

(1)

50W

50W

10A

(2)

75W

100W

20A

(3)

100W

100W

20A

Max. Output For 5V Outputs > 5V Outputs < 5V Outputs

(4)

75W

75W

15A

(5)

50W

75W

15A

(6)

50W

75W

10A

Product Grade/

Product Grade/

Operating Temp.

Storage Temp.

E  = -10°C  to  +100°C E = -20°C  to +105°C

C = -25°C  to  +100°C C = -40°C  to +105°C

I = -40°C  to  +100°C I = -55°C  to +105°C

M = -55°C  to  +100°C M = -65°C  to +105°C

Output Power/Current

V

OUT

5V

V

OUT

< 5V

Z

=

25W

Z

=

5A

Y

=

50W

Y

=

10A

X

=

75W

X

=

15A

W

=

100W

W

=

20A

Output Voltage

Z =

2V

2 =

15V

Y = 3.3V

N = 18.5V

0 =

5V

3 =

24V

X = 5.2V

L =

28V

W = 5.5V

J =

36V

V = 5.8V

K =

40V

T = 6.5V

4 =

48V

R = 7.5V

H =

52V

M =

10V

F =

72V

1 =

12V

D =

85V

P = 13.8V

B =

95V

Features

s Up to 50W/Cubic Inch

s UL, CSA, TÜV, VDE, BABT

s CE Marked

s Up to 90% Efficiency 

s Size: 2.28" x 2.4" x 0.5"

(57,9 x 61,0 x 12,7) 

s Remote Sense and Current Limit

s Logic Disable 

s Wide Range Output Adjust

s ZCS Power Architecture

s Low Noise FM Control

Mechanical Drawing

5

6

7

8

9

4

3

2

1

.080 Dia (2) places

Solder plate

over copper alloy

.040 (1,0) Dia (7) places

Solder plate

over copper alloy

.01

Aluminum Base

Product ID

this surface

Function

  +In

  -In

 +Out

 Trim

–Sense

 –Out

Pin #

  1

  2

  3

  4

  5

  6

  7

  8

  9

FULL R

+.030 (0,76)

-.000 (0)

(5,6) Min.

(7,6) Min.

(44,4) Max.

(61,0)

 (57,9)

 (3,0)

(12,7)

1.90 

.65

(16,5)

.49

(12,4)

.30

±

.015

  (7,6)

±

(0,38)

.15

2.10

(53,4)

(33,0)

.40

(10,2)

.35

±

 .015 

(8,9)

±

(0,38)

1.40

(35,6)

1.00

(25,4)

.70

 (17,8)

  Gate In 

  Gate Out

  +Sense

VI-J00

2.28

1.30 

 (3,8)

.15

 (3,8)

(48,3)

.22 

.12

.50 

.30 

2.40 

1.75 

*Brownout 75% of rated load; transient voltage for 1 second.

Rev 3   1 of 2

For the latest Vicor Product Information: www.vicorpower.com

background image

12 

1-800-735-6200

73

Converter Specifications

(typical at T

BP

= 25°C, nominal line and 75% load, unless otherwise specified)

VI-J00 E-Grade

VI-J00 C-, I-, M-Grade

PARAMETER

MIN.

TYP.

MAX.

MIN.

TYP.

MAX.

UNITS

TEST CONDITIONS

Input Characteristics

Inrush charge

60x10

-6

60x10

-6

100x10

-6

Coulombs

Nominal line

Input reflected ripple current – pp

10%

10%

I

IN

Nominal line, full load

Input ripple rejection

dB

120 Hz, nominal line

dB

2400 Hz, nominal line

No load power dissipation

1.35

2

1.35

2

Watts

Output Characteristics

Setpoint accuracy

1.0%

2.0%

0.5%

1.0%

V

NOM

Load/line regulation

0.5%

0.05%

0.2%

V

NOM

LL to HL, 10% to Full Load

Load/line regulation

1.0%

0.2%

0.5%

V

NOM

LL to HL, No Load to 10%

Output temperature drift

0.02

0.01

0.02

%/°C

Over rated temperature

Long term drift

0.02

0.02

%/1K hours

Output ripple - pp: 

2V, 3.3V

200

100

150

mV

20 MHz bandwidth

5V

5%

2%

3%

20 MHz bandwidth

10-48V

3%

0.75%

1.5%

20 MHz bandwidth

Trim range

1

50%

110%

50%

110%

V

NOM

Total remote sense compensation

0.5

0.5

Volts

0.25V max. neg. leg

Current limit

105%

135%

105%

125%

I

NOM

Automatic restart

Short circuit current

105%

140%

105%

130%

I

NOM

Control Pin Characteristics

Gate out impedance

50

50

Ohms

Gate in impedance

10

3

10

3

Ohms

Gate in high threshold

6

6

Volts

Use open collector

Gate in low threshold

0.65

0.65

Volts

Gate in low current

6

6

mA

Dielectric Withstand Characteristics

Input to output

3,000

3,000

V

RMS

Baseplate earthed

Output to baseplate

500

500

V

RMS

Input to baseplate

1,500

1,500

V

RMS

Thermal Characteristics

Efficiency

78-88%

80-90%

Baseplate to sink

0.4

0.4

°C/Watt

With Vicor P/N 04308

Mechanical Specifications

Weight

3.0 (85)

3.0 (85)

Ounces (Grams)

1

10V, 12V and 15V outputs, standard trim range ±10%. Consult factory for wider trim range.

For product compliance with agency standards please refer to pages 67 - 69.

25+20Log

Vin  

)

Vout

30+20Log

Vin  

)

Vout

20+20Log

Vin  

)

Vout

Rev 3   2 of 2

For the latest Vicor Product Information: www.vicorpower.com