background image

Product Highlights

The MI-Series is designed for

military applications and is based

on Vicor’s 1st Generation family of

zero-current/zero-voltage switching,

component level DC-DC converters.

Operating at frequencies in excess

of 1MHz, the MI-Series offers

state-of-the-art performance in

terms of power density, efficiency,

noise, ease of use, and reliability.

All units are manufactured in ISO

9001-registered facilities. Full

epoxy encapsulation in Vicor’s

industry standard package

enables the MI-Series to meet

MIL-STD-810 environmental

requirements for humidity,

fungus, salt, fog, explosive

atmosphere, acceleration,

vibration, and shock. (See page 32.)

Standard features such as wide

output trimming/programming,

current limiting, remote sense,

output inhibit, and latching 

OVP and OTP combine to offer 

a high degree of protection,

versatility, and reliability for

military power systems.

MI-200

TM

PARAMETER

MIN

TYP

MAX

UNITS

TEST CONDITIONS

Input Characteristics

Input voltage range

See input voltage chart

No load power dissipation

1.35

2.0

Watts

Output Characteristics

Set point accuracy

0.5

1.0

% Vnom

Load/line regulation

0.05

0.2

% Vnom

LL to HL, 10% to FL

0.2

0.5

% Vnom

LL to HL, NL to 10%

Output temperature drift

0.01

0.02

%/°C

Output noise - pp

1.0

1.5

% Vnom

Whichever is greater

100

150 mV 20MHz 

BW

Output voltage trimming

(1)

50

110

% Vnom

Remote sense compensation

0.5

Vdc

OVP set point

(2)

115

125

135

% Vnom

Latching

Current limit

105

125

% Inom

Auto restart

Short circuit current

(3)

20

130

% Inom

Control Pin Characteristics

Gate-in high threshold

6

Vdc

Gate-in low threshold

0.65

Vdc

Gate-in low current

6

mA

Power sharing accuracy

0.95

1.05

Isolation Characteristics

Isolation (input to output)

3,000

Vrms

Isolation (output to baseplate)

500

Vrms

Isolation (input to baseplate)

1,500

Vrms

Input/output capacitance

50

75

pF

Environmental (MIL-STD-810)

Altitude - method 500.2

70,000 

feet

Procedure II

Humidity - method 507.2

86 / 240

% / hours

Procedure 1, cycle 1

Acceleration - method 513.3

g's

Procedure 2

Vibration - method 514.3

20

g's

Procedure 1, category 6

Shock - method 516.3

40

g's

Procedure 1

Reliability (MIL-HDBK-217F)

25°C Ground Benign: G.B.

2,478,477

hours

50°C Naval Sheltered: N.S.

584,920

hours

65°C Airborne Inhabited Cargo: A.I.C.

483,303

hours

Thermal Characteristics

Efficiency

80-90

%

Baseplate to sink

0.07

°C/W

With thermal pads

Thermal shutdown

90

95

105

°C

Latching

Baseplate operating temperature

+85

°C

See product grade 

Storage temperature

+100

°C

See product grade 

Mechanical Specifications

Weight

6.0 (170)

ounces (grams)

Converter/Booster Specifications

(At TBP = 25°C, nominal line and 75% load, unless otherwise specified)

Features

Military DC-DC Converters 50 to 100W

(1)

10V, 12V, and 15V outputs, standard trim range ±10%. Consult factory for wider trim range.

(2)

No over temperature or voltage protection in booster modules.

(3)

Output voltages of 5V or less incorporate foldback current limiting; outputs of 10V and above provide

constant current limiting.

Inputs:

28Vdc per MIL-STD-704D/E

155Vdc per MIL-STD-1399A

270Vdc per MIL-STD-704D/E

Single output: 2 – 48Vdc

Up to 23W/in

3

MIL-STD-810 environments

Up to 90% efficiency

Remote sense

Current limit

OVP and thermal shutdown

Power boosters for 

higher power outputs

ZVS/ZCS power architecture

Low noise FM control

Size: 4.6" x 2.4" x 0.5"

(116,8 x 61,0 x 12,7mm)

}

MI-200   10/02    1 of 2

background image

Configuration Chart

Input Voltage

Nominal

Range

Transient

2 =

28V

18 – 50V

(1)

60V

5 = 155V

100 – 210V

230V

6 = 270V

125 – 400V

(2)

475V

7 = 165V

100 – 310V

MI - 2

-

Semi-custom driver and booster

modules available: Consult factory.

(1) 16V operation at 75% load.

(2) These units rated at 75% 

load from 125-150Vin:

MI-26Z-xV

MI-26Y-xV

MI-260-xW

28Vdc input per MIL-STD 704D/E

155Vdc input per DOD-STD-1399A

270Vdc input per MIL-STD-704D/E

Product Grade Specifications

+0.030 (0,76)

-0.000 (0)

Product ID

this surface

FULL R

5

6

7

8

9

4

3

2

1

Pin #

 1

 2

 3

 4

 5

 6*

 7*

 8*

 9

Function

  +In

Gate In

Gate Out

  -In

 +Out

+Sense

 Trim

-Sense

 -Out

* Do not connect on

  Booster modules

Aluminum Base

.01

0.040 (1,0) Dia (7) places

Solder plate

over copper alloy

0.080 (2,0) Dia (2) places

Solder plate

over copper alloy

 0.30

±

0.015 

(7,6)

±

(0,38)

1.80

(45,7)

4.20

0.50

0.22

 (5,6) MIN

0.12

4.60 

2.40

 1.75 

0.30

0.15

(3,8)

2.10

(53,3)

0.40

 (10,2)

 0.35

±

0.015

  (8,9)

±

(0,38)

1.40

(35,6)

1.00

(25,4)

0.70

(17,8)

3.60

MI-200 Mechanical Drawing

0.50

(12,7)

0.15

(3,8)

MI-200

(116,8)

 (91,4)

 (3,0)

 (7,6)Min

 (12,7)

 (61,0)

(44,5)

 (106,7)

*Test data available for review or download from vicorpower.com

Mechanical Drawing

Output Power/Current

5V

<5V

Y

=

50W

10A

X

=

75W

15A

W

=

100W

20A

V

=

o

30A

For additional power, 100W and 75W booster

modules available. Change MI-2xx-xx to MI-Bxx-xx.

Product Grade

Operating Temp.

I  

-40°C to +85°C

M

=

-55°C to +85°C

PARAMETER

PRODUCT GRADE

I - Grade M - Grade 

Storage temperature

-55°C to +100°C

-65°C to +100°C

Operating temperature (baseplate)

-40°C to +85°C

-55°C to +85°C

Power cycling burn-in

12 hours, 25 cycles

96 hours, 200 cycles

Temperature cycled with power off

48 hours, 12-16 cycles 

48 hours, 12-16 cycles

-55°C to +100°C

-65°C to +100°C

Test data supplied at these temperatures*

-40°C, +80°C

-55°C, +80°C

Warranty

2 years

2 years

Environmental compliance

MIL-STD-810

MIL-STD-810

Derating

NAVMAT P-4855-1A

NAVMAT P-4855-1A

Output Voltage

Z = 2V

T = 6.5V

N = 18.5V

Y = 3.3V

R = 7.5V

3 = 24V

0 = 5V

M= 10V

L = 28V

X = 5.2V

1 = 12V

J = 36V

W= 5.5V

P = 13.8V

K = 40V

V = 5.8V

2 = 15V

4 = 48V