background image

 

90

 

RX

 

0.4

0.5

0

0.1

0.3

0.2

300kHz

1.5GHz

2.5GHz 3GHz

COM-NC

COM-NO

Insertion loss, dB

Frequency

  

 

 

Arrangement

Contact

Coil (at 20

°

C, 

68

°

F

)

Contact material

Max. switching voltage

Isolation

Max. switching current

Insertion loss

10mA 24 V DC

(resistive load)

10W 2.5 GHz,

Impedance 50

3

×

10

5

10

5

V.S.W.R.(Return loss)

Min. 60 dB

Max. 0.2 dB

Max. 1.2 (Min. 20.8dB)

Input power

Max. 20W (at 40

°

C,

V.S.W.R.    1.2,Average)

2 coil latching

Single side stable

200 mW

Nominal operating power

1 coil latching

400 mW

200 mW

Initial contact resistance

1 Form C

Gold

Max. 100 m

Contact carrying power

High frequency

characteristics

(~2.5GHz,

Impedance 50

)

Expected

life (min.

operations)

5

×

10

6

Electrical

Mechanical (at 180 cpm)

Rating

Contact rating

30 V DC

0.5 A DC

Characteristics

Initial insulation resistance*

1

Operate time [Set time]*

3

 (at 20

°

C)

Max. 10ms (Approx. 6ms)

[Max. 10ms (Approx. 5ms)]

Max. 6ms (Approx. 3ms)

[Max. 10ms (Approx. 5ms)]

Max. 60

°

C

Temperature rise (at 20

°

C)*

4

Initial 

breakdown 

voltage*

2

Between open contacts

Between contact and coil

Between contact and 

earth terminal

500 Vrms

1,000 Vrms

500 Vrms

Min. 100 M

 (at 500 V DC)

Shock resistance

Vibration 

resistance

Unit weight

Approx. 5 g 

.18 oz

Min. 200 m/s

2

 {20 G}

Min. 1,000 m/s

2

 {100 G}

Functional*

5

Destructive*

6

Functional*

7

Destructive

10 to 55 Hz

at double amplitude of 3 mm

10 to 55 Hz

at double amplitude of 5 mm

Conditions for operation,

transport and storage*

8

(Not freezing and condensing 

at low temperature)

Ambient temp.

Humidity

–40

°

C to 60

°

–40

°

F to 140

°

F

5 to 85% R.H.

Release time (without diode) [Reset time]*

3

Max. 20W(at 40

°

C,

V.S.W.R.  1.2, Average)

10W (2.5 GHz, Impedance

50 

, V.S.W.R.  1.2)

10mA 24V DC(resistive load)

Remarks

*  Specifications will vary with foreign standards certification ratings.

*

1

 Measurement at same location as “Initial breakdown voltage” section.

*

2

 Detection current: 10mA

*

3

 Nominal operating voltage applied to the coil, excluding contact bounce time.

*

4

 By resistive method, nominal voltage applied to the coil: Contact carrying power:

20W, at 2.5GHz, Impedance 50

, V.S.W.R.

&

1.2

*

5

 Half-wave pulse of sine wave: 11ms, detection time: 10

µ

s.

*

6

 Half-wave pulse of sine wave: 6ms

*

7

 Detection time: 10

µ

s

*

8

 Refer to 5. Conditions for operation, transport and storage mentioned in 

AMBIENT ENVIRONMENT (Page 61)

 

1

0

RX

A

Ex.

Contact arrangement

1: 1 Form C

Product name

RX

Note: Standard packing; Carton: 50 pcs. Case 500 pcs.

0: Single side stable

1: 1 coil latching

2: 2 coil latching

03: 3

4H: 4.5

06: 6

09: 9

12: 12

24: 24

Operating function

Coil voltage, V DC

12

 

1. Excellent high frequency character-

istics (~2.5GHz, Impedance 50

 

 

)

 

• Insertion loss: 0.2 dB or less

• Isolation: 60 dB or more

• V.S.W.R./ Return loss: 1.2dB or less/ 

   20.8dB or more

 

2. High sensitivity

 

• Nominal operating power: 200 mW

 

3. Small size

 

• Size: 20.5(L) 

 

×

 

 12.4(W) 

 

×

 

 9.4(H) mm

.807(L) 

 

×

 

 .488(W) 

 

×

 

 .370(H) inch

*Also available for unit support (contact us

for more details).

  

SMALL MICRO WAVE RELAY

RX-RELAYS

 

20.5

.807

9.4

.370

12.4

.488

 

TYPICAL APPLICATIONS

 

• Cellular phone base station (W-CDMA, 

   FPLMTS, IMT-2000, PCS, DCS)

• Cellular phone-related measurement 

   devices (SP3T/SP4T switches, etc)

• Wireless LAN

• Wireless Local Loop

 

SPECIFICATIONS

 

mm

 inch

 

• Insertion loss

 

ORDERING INFORMATION

background image

 

91

 

RX

  

 

Part No.

ARX1003

ARX104H

ARX1006

ARX1009

ARX1012

ARX1024

ARX1103

ARX114H

ARX1106

ARX1109

ARX1112

ARX1124

ARX1203

ARX124H

ARX1206

ARX1209

ARX1212

ARX1224

3

2.25

0.3

45

66.7

200

3.3

4.5

3.375

0.45

101

44.4

200

4.95

6

4.5

0.6

180

33.3

200

6.6

9

6.75

0.9

405

22.2

200

9.9

24

18

2.4

2,880

8.3

200

26.4

12

9

1.2

720

16.7

45

66.7

101

44.4

180

33.3

405

22.2

2,880

8.3

720

22.5

50.6

90

202.5

1,440

360

16.7

133.3

88.9

66.7

44.4

16.7

33.3

200

200

200

200

200

200

200

400

400

400

400

400

400

13.2

Nominal 

voltage, 

V DC

Pick-up 

voltage, V DC

(max.)(initial)

Drop-out 

voltage, V DC

(min.)(initial)

Nominal 

voltage, 

V DC

Set 

voltage, V DC

(max.)(initial)

Reset 

voltage, V DC

(max.)(initial)

Coil resistance, 

 (

±

10%)

Nominal 

operating current,

 mA (

±

10%)

Nominal 

operating power, 

mW

Max. allowable 

voltage, V DC

Max. allowable 

voltage, V DC

• Single side stable type

Part No.

3

2.25

3.3

4.5

3.375

4.95

6

4.5

6.6

9

6.75

9.9

24

18

26.4

12

9

13.2

Coil resistance, 

 (

±

10%)

Nominal 

operating current,

 mA (

±

10%)

Nominal 

operating power, 

mW

Nominal 

voltage, 

V DC

Set 

voltage, V DC

(max.)(initial)

Reset 

voltage, V DC

(max.)(initial)

Max. allowable 

voltage, V DC

Part No.

Coil resistance, 

 (

±

10%)

Nominal 

operating current,

 mA (

±

10%)

Nominal 

operating power, 

mW

• 1 coil latching type

3

2.25

3.3

4.5

3.375

4.95

6

4.5

6.6

9

6.75

9.9

24

18

26.4

12

9

2.25

3.375

4.5

6.75

18

9

2.25

3.375

4.5

6.75

18

9

13.2

• 2 coil latching type

 

TYPES ANE COIL DATA (at 20°C 

68°F

)

DIMENSIONS

 

mm inch

 

 

Schematic (Bottom view)

Tolerance: 

±

0.1 

±

.004

General tolerance: 

±

0.3 

±

.012

(Reset condition)

PC board pattern (Bottom view)

(Reset condition)

(Deenergized condition)

(2.74)

(.108)

(2.04)

(.080)

2.54

.100

2-0.6

×

0.3

2-.024

×

.012

7-0.40 to 0.45 dia.

7-.016 to .018 dia.

2.63

.104

Solder to the PC board earth.

9.2

.362

0.2

.008

3.0

.118

20.5

.807

12.4

.488

0.9 dia hole

.035 dia hole

7.62

.300

2.54

.100

7.62

.300

0.90

.035

(2 coil latching type only)

R 0.45

7

1

14 13 12 11 10 9

8

NC

COM

NO

7

1

8

9

10

11

12

13

14

RESET

COM

SET

1

7

6

8

9

10

11

12

13

14

RESET

COM

SET

Single side stable

1 coil latching

2 coil latching

background image

 

92

 

RX

 

REFERENCE DATA

 

0.4

0.5

0

0.1

0.3

0.2

300kHz

1.5GHz

2.5GHz 3GHz

COM-NC

COM-NO

Insertion loss, dB

Frequency

 

80

100

0

20

60

40

300kHz

1.5GHz

2.5GHz 3GHz

COM-NC

COM-NO

Isolation, dB

Frequency

 

40

50

0

10

30

20

300kHz

1.5GHz

2.5GHz 3GHz

COM-NO

5.0

2.0

1.5

1.2

1.1

COM-NC

Return loss, dB

Frequency

V.S.W.R.

 

1. High frequency characteristics

 

Sample: ARX1012

Measuring method: Measured with HP network analyzer (HP8753C).

The details for the high freqency characteristics and the measurement

procedures and conditions are listed in the RX relay test report.

• Insertion loss

• Isolation

• V.S.W.R. (Return loss)

 

NOTES

 

1. Coil operating power

 

Pure DC current should be applied to the

coil. The wave form should be rectangu-

lar. lf it includes ripple, the ripple factor

should be less than 5%.

However, check it with the actual circuit

since the characteristics may be slightly

different. The nominal operating voltage

should be applied to the coil for more

than 30 ms to set/reset the latching type

relay.

 

2. Coil connection

 

When connecting coils, refer to the wiring

diagram to prevent mis-operation or mal-

function.

 

3. External magnetic field

 

Since RX relays are highly sensitive po-

larized relays, their characteristics will be

affected by a strong external magnetic

field. Avoid using the relay under that

condition.

 

4. Cleaning

 

For automatic cleaning, the boiling meth-

od is recommended. Avoid ultrasonic

cleaning which subjects the relays to high

frequency vibrations, which may cause

the contacts to stick.

lt is recommended that a fluorinated hy-

drocarbon or other alcoholic solvents be

used.

 

5. Soldering

 

The soldering shall be performed under

following condition.

Max. 260°C 

500°F

 10s

Max. 350°C 

662°F

 3s

In addition, when soldering the case to

the PC board, the plating may swell

depending on the soldering conditions.

 

For Cautions for Use, see Relay Technical Information (Page 48 to 76).

 

9/1/2000

All Rights Reserved, © Copyright Matsushita Electric Works, Ltd.

 

Go To Online Catalog


Document Outline