background image

6A05

THRU

6A10

6 Amp Rectifier

50 - 1000 Volts

R-6

Features

• 

Low Cost

• 

Low Forward Voltage Drop

• 

High Current Capability

• 

High Surge Current Capability

• 

Low Leakage

DIMENSIONS

INCHES

MM

DIM

MIN

MAX

MIN

MAX

NOTE

A

.340

.360

8.60

9.10

B

.340

.360

8.60

9.10

C

.048

.052

1.20

1.30

D

1.000

---

25.40

---

Maximum Ratings

• 

Operating Temperature: -55

°

C to +150

°

C

• 

Storage Temperature: -55

°

C to +150

°

C

• 

Maximum Thermal Resistance; 10

°

C/W Junction To Ambient

MCC

Catalog

Number

Device

Marking

Maximum

Recurrent

Peak

Reverse

Voltage

Maximum

RMS

Voltage

Maximum

DC

Blocking

Voltage

6A05

---

50V

35V

50V

6A1

---

100V

70V

100V

6A2

---

200V

140V

200V

6A4

---

400V

280V

400V

6A6

---

600V

420V

600V

6A8

---

800V

560V

800V

6A10

---

1000V

700V

1000V

Electrical Characteristics @ 25

°

C Unless Otherwise Specified

Average Forward

Current

I

F(AV)

6.0A

T

A

 = 60

°

C

Peak Forward Surge

Current

I

FSM

400A

8.3ms, half sine

Maximum

Instantaneous

Forward Voltage

V

F

0.95V

I

FM

 = 6.0A;

T

J

 = 25

°

C*

Maximum DC

Reverse Current At

Rated DC Blocking

Voltage

I

R

10

µ

A

100

µ

A

T

J

 = 25

°

C

T

J

 = 100

°

C

Typical Junction

Capacitance

C

J

150pF

Measured at

1.0MHz, V

R

=4.0V

*Pulse test: Pulse width 300 

µ

sec, Duty cycle 1%

A

B

D

D

C

Cathode

Mark

www.

mccsemi

.com

  omponents

21201 Itasca Street Chatsworth



  !"#

$ %    !"#

M C C

background image

6A05 thru 6A10

Average Forward Rectified Current  -  Amperes 

versus

Ambient Temperature  - 

°

C

Figure 2

Forward Derating Curve

0

175

50

75

100

125

0

1

2

3

Single Phase, Half Wave

60Hz Resistive or Inductive Load

Amps

°

C

150

4

5

6

Thermal Resistance - 

°

C/W  versus

Equal Lead Length To Heat Sink - Inches

Instantaneous Forward Current - Amperes versus

Instantaneous Forward Voltage - Volts

Figure 1

Typical Forward Characteristics

40

60

200

100

Amps

.6

.8

1.0

1.2

1.4

1.6

.1

.2

.4

.6

1

2

4

6

10

20

25

°

C

Volts

Figure 3

Typical Thermal Resistance versus Lead Length

.1

.2

.3

.5

.6

.7

.4

.8

.9

0

10

20

°

C/W

Inches

15

5

1.0

1.1

PC BOARD

PC BOARD

www.

mccsemi

.com

M C C

background image

6A05 thru 6A10

1

100

4

0

100

5

200

300

8

Figure 5

Maximum Non-Repetitive Forward Surge Current

Peak Forward Surge Current - Amperes versus

Number Of Cycles At 60Hz - Cycles

Amps

Cycles

2

6

10

20

60 80

40

400

500

600

Figure 4

Typical Reverse Characteristics

Instantaneous Reverse Leakage Current - MicroAmperes 

versus

Percent Of Rated Peak Reverse Voltage - Volts

Volts

4

6

20

10

µ

Amps

20

120

40

60

80

100

.01

.02

.04

.06

.1

.2

.4

.6

1

2

T

J

=25

°

C

40

60

100

140

T

J

=100

°

C

www.

mccsemi

.com