background image

MB05M

THRU

MB10M

0.5Amp Single Phase

Glass Passivated

Bridge Rectifier

50 to 1000 Volts

Features

• 

Through Hole Package

• 

Glass Passivated Diode Construction

• 

Moisture Resistant Epoxy Case

• 

High Surge Current Capability

Maximum Ratings

• 

Operating Temperature: -55

°

C to +150

°

C

• 

Storage Temperature: -55

°

C to +150

°

C

MCC

Catalog

Number

Device

Marking

Maximum

Recurrent

Peak Reverse

Voltage

Maximum

RMS

Voltage

Maximum

DC

Blocking

Voltage

MB05M            --- 50V 35V 50V

MB1M  --- 100V 70V 100V

MB2M  --- 200V 140V 200V

MB4M  --- 400V 280V 400V

MB6M              --- 600V 420V 600V

MB8M  --- 800V 560V 800V

MB10M            --- 1000V 700V 1000V

Electrical Characteristics @ 25

°

C Unless Otherwise Specified

Average Forward

Current

I

F(AV) 

          0.5A T

A

 = 40

°

C

Peak Forward Surge

Current

I

FSM 

30A 8.3ms, half sine

Maximum

Instantaneous

Forward Voltage

V

1.0V I

FM

 = 0.5A;

T

A

 = 25

°

C

Maximum DC

Reverse Current At

Rated DC Blocking

Voltage

I

µ

A

0.5mA

T

A

 = 25

°

C

T

A

 = 125

°

C

Typical Junction

Capacitance

C

J

25pF

Measured at

1.0MHz, V

R

=4.0V

*Pulse Test: Pulse Width 300

µ

sec, Duty Cycle 1%

  

MB-1

www.

mccsemi

.com



    















 



























 

















































































  

  

  

  











 !"#$%



!&'(























∼∼∼∼

∼∼∼∼





)

  omponents

21201 Itasca Street Chatsworth



  !"#

$ %    !"#

M C C

background image

MB05M  thru  MB10M

  

Instantaneous Reverse Leakage Current - MicroAmperes 

versus

Percent Of Rated Peak Reverse Voltage - Volts

Average Forward Rectified Current  -  Amperes 

versus

Ambient Temperature  - 

°

C

Figure 3

Forward Derating Curve

 0   40 175

50 75 100 125

0

.2

.4

.6

Single Phase, Half Wave

60Hz Resistive or Inductive Load

Amps

°

C

150

.8

1.0

1.2

Instantaneous Forward Current - Amperes versus

Instantaneous Forward Voltage - Volts

Figure 1

Typical Forward Characteristics

4

6

20

10

Amps

1

100

4

0

10

5

20

30

8

Figure 4

Peak Forward Surge Current

Peak Forward Surge Current - Amperes versus

Number Of Cycles At 60Hz - Cycles

Amps

Cycles

2

6

10

20

60 80

40

40

50

60

.4

.6

.8

1.0

1.2

1.4

.01

.02

.04

.06

.1

.2

.4

.6

1

2

25

°

C

Volts

Figure 2

Typical Reverse Characteristics

Volts

4

6

20

10

µ

Amps

20

120

40

60

80

100

.01

.02

.04

.06

.1

.2

.4

.6

1

2

T

A

=25

°

C

40

60

100

140

www.

mccsemi

.com

M C C